Posted on 28 Sep, 2020, in Uncategorized
Hi,I have few questions about ICX1. I want to do rollback if I didn’t save manuallyin Aruba using these command alias, save, job2. I want to save config without credentials. This useful when you restore config without overwriting existing usersin Aruba using “no include-credentials”tq
Posted on 27 Sep, 2020, in Uncategorized
Switch lost it’s configuration after a power outage.During boot i am getting the following messages:Starting kernel …booting with 4.4 kerneldd cmd: UBIConfig partition mountedUBIFS error (ubi1:0 pid 566): ubifs_recover_leb: corrupt empty space LEB 11:249856, corruption starts at 767809UBIFS error (ubi1:0 pid 566): ubifs_scanned_corruption: corruption at LEB 11:1017665UBIFS error (ubi1:0 pid 566): ubifs_scanned_corruption: first 8192 bytes from LEB 11:1017665UBIFS error (ubi1:0 pid 566): ubifs_recover_leb: LEB 11 scanning failedmount: mounting ubi1:resources on /opt failed: Structure needs cleaningResource partition is mounted!!Starting TPM InfraGroup tss and User tss createdkernel.hostname = localhosthostname set to localhostStarting TCSD DaemonTCSD Up and Runningdma_mem_base: 0x96000000, dma_mem_len: 0x8000000, warm_mem_base: 0x9f500000, warm_mem_len: 0xb00000Creating TUN deviceDumping the partition’s content …Starting the FastIron.Any help appreciated!
Posted on 27 Sep, 2020, in Uncategorized
We have a
Brocade ICX7250 that will not stack. We atleast 40 sites with the same stack configuration. So this isn’t a new setup for us.When we do the ‘stack enable’ we receive the error: “stack port e 1/2/1 has
1g speed-duplex settings”. With stack cables
you don’t need the license for 10G
for stacking. Stacking cables are connected via the standard, 1/2/1 to 1/2/3 to the second switch, and vice-versa for the return to complete the stack circle.
Is this a known
issue with a fix for it?
Thanks. Steve.
Posted on 26 Sep, 2020, in Uncategorized
Switch lost it’s configuration after a power outage.During boot i am getting the following messages:Starting kernel …booting with 4.4 kerneldd cmd: UBIConfig partition mountedUBIFS error (ubi1:0 pid 566): ubifs_recover_leb: corrupt empty space LEB 11:249856, corruption starts at 767809UBIFS error (ubi1:0 pid 566): ubifs_scanned_corruption: corruption at LEB 11:1017665UBIFS error (ubi1:0 pid 566): ubifs_scanned_corruption: first 8192 bytes from LEB 11:1017665UBIFS error (ubi1:0 pid 566): ubifs_recover_leb: LEB 11 scanning failedmount: mounting ubi1:resources on /opt failed: Structure needs cleaningResource partition is mounted!!Starting TPM InfraGroup tss and User tss createdkernel.hostname = localhosthostname set to localhostStarting TCSD DaemonTCSD Up and Runningdma_mem_base: 0x96000000, dma_mem_len: 0x8000000, warm_mem_base: 0x9f500000, warm_mem_len: 0xb00000Creating TUN deviceDumping the partition’s content …Starting the FastIron.Any help appreciated!
Posted on 25 Sep, 2020, in Uncategorized
Hi guys, i have questions. I have to connect the ICX 6450 POE switch through a trunk port with a cisco switch. Is it possible? Is it possible to connect two Brocade ICX 6450 POE in trunk ?thanks 1000
Posted on 25 Sep, 2020, in Uncategorized
I purchased a Lennar home last year and it came with an ICX7150 switch and 2 R510 AP’s running Unleashed with mesh configuration. Unfortunately, the house was built upon wireless connections only and I prefer to have atleast a few wired connections. However, I would like to avoid cutting into the drywall and so forth to un an additional line to the attic. My current setup is ISP (Internet)—–>Uverse router —–>ICX switch —–>Master AP and Member AP. Since the cable is already ran into the attic for the member AP, I would like to somehow use this cable to connect possibly a netgear unmanaged switch. Could I connect from the ICX 7150 to another netgear switch that has POE capabilities and reconnect that to my member AP (and then use the other available ports to run cables to each bedroom? I currently have been using the second line from my member Ap to connect a cheap netgear switch that has two CAT6 lines ran for my sons PS4 and my PC. I doubt I should have this connected as such but it’s been working so far. However, I would like to correct run everything but have a VERY limited budget and do not want to purchase another ICX switch.
Posted on 24 Sep, 2020, in Uncategorized
Ruckus ICX FastIron 08.0.95a (GA) Software Release (.zip)..zip file contains switch Firmware, MIBs, and Signature files, and applies to: ICX7150, ICX7250, ICX7450, ICX7550, ICX7650, ICX7750, ICX7850Review the RUCKUS ICX FastIron 08.0.95a (GA) Release Notes prior to installation.
Posted on 24 Sep, 2020, in Uncategorized
How can I configure DHCP on a Cisco switch/router to direct APs to a ZoneDirector, SCG, or vSZ?
Posted on 22 Sep, 2020, in Uncategorized
RUCKUS ICX FastIron 08.0.95a (GA) Release NotesApplies to: ICX 7150, 7250, 7450, 7550, 7650, 7750, 7850 model switches.
Posted on 21 Sep, 2020, in Uncategorized
I am looking to manage ports on my ICX 7150-C12 switch that is joined in Unleashed, running on an R320. I also have 2x r510s. The 200.9 documentation shows expanding “show port info” will show this interface:http://docs.ruckuswireless.com/unleashed/200.9/GUID-E40024A2-6964-45D4-AF03-5ACCB974B1C9-low.pngMy Unleashed web interface only shows the pie chart above. Is there an extra step to enable port management in Unleashed? Or do I need to do this via the switch’s Web GUI?
Posted on 20 Sep, 2020, in Uncategorized
Lost POE on two 6450 switches after power outage.Have multiple ICX 6450 switches deployed in a large store in Oregon. Thanks to power outages last night… all the switches came up, but two are not longer providing POE. Tried reloading, hard reboot by power off/onConfirmed llpd & cdp enabledHave no tech support, but do have RMA if needed. Any suggestions?Power Capacity: Total is 740000 mWatts. Current Free is 740000 mWatts.Power Allocations: Requests Honored 0 times Port Admin Oper —Power(mWatts)— PD Type PD Class Pri Fault/ State State Consumed Allocated Error————————————————————————– 1/1/1 On Off 0 0 n/a n/a 3 n/a 1/1/2 On Off 0 0 n/a n/a 3 n/a 1/1/3 On Off 0 0 n/a n/a 3 n/a detail show inline power detailed information <cr>show inline power detailPower Supply Data On stack 1:++++++++++++++++++Power Supply Data:++++++++++++++++++Power Supply #1: Max Curr: 13.7 Amps Voltage: 54.0 Volts Capacity: 740 Wattspower supply 2 is not presentpower supply 3 is not presentPOE Details Info. On Stack 1 :General PoE Data:+++++++++++++++++FirmwareVersion—————-02.1.0 Build 004Cumulative Port State Data:+++++++++++++++++++++++++++#Ports #Ports #Ports #Ports #Ports #Ports #PortsAdmin-On Admin-Off Oper-On Oper-Off Off-Denied Off-No-PD Off-Fault————————————————————————-48 0 0 48 0 0 0Cumulative Port Power Data:+++++++++++++++++++++++++++#Ports #Ports #Ports Power PowerPri: 1 Pri: 2 Pri: 3 Consumption Allocation———————————————–0 0 48 0.0 W 0.0 WAny suggestion would be welcomed!Cheers – James
Posted on 17 Sep, 2020, in Uncategorized
I’m Looking for guidance from Ruckus on earthing of their Acccess points, Indoor and outdoor. I’m trying to find out what ruckus have designed the earthing terminals for on there access points. Is it for fault current protection? Static discharge? Over current protection? Surge protection to work in conjunction with an SPD on the Ethernet connection? Or possibly all the above? Is there any concerns for potential earth leakage (transient voltages from latent defects other electrical circuits) to cause potential faults to the antenna or internal circuitry. Look for any potential guidance possible.
Posted on 10 Sep, 2020, in Uncategorized
FastIron 08.0.95 (GA) DHCP Configuration GuideHTML Version: HereApplies to: ICX 7150, 7250, 7450, 7550, 7650, 7750, 7850 model switches.
Posted on 10 Sep, 2020, in Uncategorized
FastIron 08.0.95 (GA) Web Management GuideHTML Version: HereApplies to: ICX 7150, 7250, 7450, 7550, 7650, 7750, 7850 model switches.
Posted on 10 Sep, 2020, in Uncategorized
FastIron 08.0.95 (GA) Traffic Management Configuration GuideHTML Version: HereApplies to: ICX 7150, 7250, 7450, 7550, 7650, 7750, 7850 model switches.