Month: September 2018

Brocade ICX Alias Command

Posted on 28 Sep, 2018, in Uncategorized

Brocade ICX Alias Command

Why is ICX6610 FAN always high speed when 2 PSU devices are installed?

Posted on 28 Sep, 2018, in Uncategorized

ICX6610 FAN is always high speed when 2 PSU devices installed.

How to configure IP load-sharing in FastIron switches?

Posted on 28 Sep, 2018, in Uncategorized

How to configure IP load-sharing in FastIron switches?

ruckus zone director cluster config

Posted on 21 Sep, 2018, in Uncategorized

can anyone guide withe Zone director cluster config
here requirement is that we have two ZD on two floor .
when user is in 1st floor , they are authenticated and if they move in the 2nd floor he must not be asked for connecting again .
Please suggest what need to be done for this .
Regards
Abhinav

Ruckus R710 is not working with Unleashed in UniFi Switch 48 Port 750 Watt

Posted on 21 Sep, 2018, in Uncategorized

I upgraded all the AP’s to Ruckus R710 in Unleashed x3 but they are not powering on even activating 24V Passive POE on UniFi switches . But they are working with the 12V DC power. How can I make them work.

Ruckus R720 Errors

Posted on 21 Sep, 2018, in Uncategorized

Running a Ruckus R720 (106.0.0.99.1363) as a standalone unit and everything seems to be running fine from a WiFi perspective. That being said every 5 seconds or so I am seeing the following in the log:Oct  3 21:17:28 AUS-AP-EAST daemon.err wsgclient[493]: communicatorInit:290 Call ‘getWSGServerUrl()’ failed, ret:8/url not foundOct  3 21:17:28 AUS-AP-EAST daemon.err wsgclient[493]: registration:708 Failed to init socket! ret:8 url:Oct  3 21:17:33 AUS-AP-EAST daemon.err wsgclient[493]: communicatorInit:290 Call ‘getWSGServerUrl()’ failed, ret:8/url not foundOct  3 21:17:33 AUS-AP-EAST daemon.err wsgclient[493]: registration:708 Failed to init socket! ret:8 url:Oct  3 21:17:38 AUS-AP-EAST daemon.err wsgclient[493]: communicatorInit:290 Call ‘getWSGServerUrl()’ failed, ret:8/url not foundOct  3 21:17:38 AUS-AP-EAST daemon.err wsgclient[493]: registration:708 Failed to init socket! ret:8 url:Oct  3 21:17:43 AUS-AP-EAST daemon.err wsgclient[493]: communicatorInit:290 Call ‘getWSGServerUrl()’ failed, ret:8/url not foundOct  3 21:17:43 AUS-AP-EAST daemon.err wsgclient[493]: registration:708 Failed to init socket! ret:8 url:Oct  3 21:17:48 AUS-AP-EAST daemon.err wsgclient[493]: communicatorInit:290 Call ‘getWSGServerUrl()’ failed, ret:8/url not foundOct  3 21:17:48 AUS-AP-EAST daemon.err wsgclient[493]: registration:708 Failed to init socket! ret:8 url:Does anyone have any idea on how to remedy this?thanks,Peter

How to auto-provision Brocade switches by DHCP

Posted on 21 Sep, 2018, in Uncategorized

Going through the documentation (which is pretty shoddy) I can’t seem to figure this out. My best guess, from what I’ve read, is:Unzip firmware distribution into TFTP server rootAdd option 66 pointing to DHCP server (e.g. 192.168.0.1)Add option 67 pointing to manifest file (e.g. FI08070a_Manifest.txt)Reboot switchHowever, after getting a DHCP address there are no attempts by the switch to download the manifest file (but it does try to download a config file.) How does this work?

How many modules of 4-port 1/10 GbE 10GBASE-T copper can be attached at ICX7450?

Posted on 21 Sep, 2018, in Uncategorized

How many modules of 4-port 1/10 GbE 10GBASE-T copper  can be attached at ICX7450?

Setting Time-Based Scheduling of WLANs on Ruckus Cloud

Posted on 21 Sep, 2018, in Uncategorized

There is an icon under Venue, Networks, to setup time based service schedule for SSID WLANs.

Add second ICX switch

Posted on 19 Sep, 2018, in Uncategorized

First of all, great product and great community! Thank you!So today I went out and bought another ICX switch (7150-c12p) and would like to use it on another room. It is running the router image (layer 3)My core router has two vlans: vlan 30 (users) and vlan 200 (phones).How would I go if I want to configure this new router to support both vlans.Here is my try (didn’t work btw):lag test static id 1ports ethernet 1/2/1 to 1/2/2vlan 30 name usersuntagged ethernet 1/1/1 to 1/1/12tagged lag 1vlan 200 name phonestagged ethernet 1/1/1 to 1/1/12 lag 1ip route 0.0.0.0/0 192.168.1.1192.168.1.1 is my gateway.Am I over complicating things?Thanks!

Windows DHCP server migration broke Ruckus Wireless Network

Posted on 06 Sep, 2018, in Uncategorized

We migrated our DHCP server from an old server to a new one when we decomissioned our admin network and now just have a single domain and network.DHCP is working fine with our wired clients.It has broken our wireless network. Ruckus Zone Director 3000 and APs ZF7363You try connect to the wireless and it wont let you connect, it fails to assign an IP address. The APs keep restarting as they are failing to get the heartbeat from the ZoneDirector. The wireless network worked fine until the DHCP was migrated then it is playing up. We have even restored the zone director to factory settings but still having the same issue.Anyone any ideas?Thanks