Posted on 29 Dec, 2018, in Uncategorized
Error descriptionDec 26 17:00:10:I: Latched low RX Power warning, port 1/1/6Dec 26 17:00:10:I: Latched low RX Power alarm, port 1/1/6Dec 26 16:52:10:I: Latched low RX Power warning, port 1/1/6Dec 26 16:52:10:I: Latched low RX Power alarm, port 1/1/6Dec 26 16:44:10:I: Latched low RX Power warning, port 1/1/6Dec 26 16:44:10:I: Latched low RX Power alarm, port 1/1/6i have checked optic status on the interface as below SSH@WL_P1_D4-4WH-FA_L3-B7450_2.30>sh optic 1/1/6 Port Temperature Voltage Tx Power Rx Power Tx Bias Current+—–+————-+————-+————-+————-+—————+1/1/6 35.5429 C 3.2895 volts -6.5560 dBm N/A 16.072 mA Normal Normal Normal NormalWill you please help me to how to resolve the issue and as well as understand meaning of above output Thanks in advance
Posted on 27 Dec, 2018, in Uncategorized
WinMD5Free is a PC version utility
Posted on 26 Dec, 2018, in Uncategorized
This article describes what needs to be done to negotiate 802.3at power between R710 AP and POE+switches
Posted on 26 Dec, 2018, in Uncategorized
Certain malformed packets incorrectly handled, can result in dramatically increased system logs, leading to free disk space depletion.
Posted on 25 Dec, 2018, in Uncategorized
Article has information about getting refund for the support and licenses ordered incorrectly by the customer
Posted on 24 Dec, 2018, in Uncategorized
Ruckus provides syslog to Barracuda, filtering username/IP address, to apply ACL policies
Posted on 20 Dec, 2018, in Uncategorized
Hello everybody,we are using a lot of Brocade ICX-7250 switches (SW-version: 08.0.80cT213)
in our access area. Now we plan to migrate to an SDN environment. We
tested ONOS (v1.14) as central SDN controller, where we identified two
problems in interaction between Brocade ICX-7250-48 and ONOS:1)
Brocade ICX-7250 does not support flows with a priority of 40.000,
which is the default priority for ONOS control flows (lldp, bddp etc.).
This problem just could be fixed by adjust the ONOS source code and
building it from scratch. Does anyone know, which is the maximum accepted value for priority supported by ICX-7250?Is there a plan to fix this constraint in newer firmware versions? 2)
After fixing the priority problem, the OpenFlow connection works until
the controller sends a OpenFlow Message from type “MULTIPART_REQUEST,
OFMPM_FLOW” to collect meter information. The switch replies with a
OpenFlow message “MULTIPARTY_REPLY”, which is malformed. Immediately
after this the connection will be closed. After this, the process begins
from the beginning, again and again. The switch log shows the following
entry:Debug: November 12 10:27:33 Invalid controller id 1, Unable to find TCP This behaviour is also posted in detail here (Google group). Is there any workaround to fix this problem?Is there a plan to fix this constraint in newer firmware versions? Thank you in advance for any helpful information!Regards,Andreas
Posted on 19 Dec, 2018, in Uncategorized
Hi AllWe have an ICX7150-24P-4X1G POE 24-port, with 10 R510 AP’s.All the AP’s are down but switch is up leading to me a POE issue. Switch has been rebooted with no change, However there is no output to the sh power inline command. would the POE module failing cause there to be no output?
Posted on 13 Dec, 2018, in Uncategorized
Hello dears,The ICX 7750 switches supports IPv6 in hardware, in order to provide wire-rate forwarding for IPv6 packets?Thank you!
Posted on 13 Dec, 2018, in Uncategorized
The ICX switches family supports QoS Traffic Shaping feature? If yes:. The switch can be perform actions to the packets that exceeds the configured maximum limit? What are the actions that switch can be perform?Thank you!
Posted on 11 Dec, 2018, in Uncategorized
I have 2 R510, how do I configure the two R510 as one Access Point with same SSID. And it will just load balance the the traffic. Thanks.
Posted on 08 Dec, 2018, in Uncategorized
I want to configure the APs to mark the IP traffic with DSCP specifics for VoIP, but am not sure how to do this.
Posted on 08 Dec, 2018, in Uncategorized
How to view planner reports – Ruckus Wireless Airmagnet planner
Posted on 05 Dec, 2018, in Uncategorized
So I have a R610 indoor AP. I want to run this in stand alone mode, using a regular router behind it to do the DHCP server. Do I have to purchase the rights to make this a standalone unit or do I have to purchase Unleashed? I thought I remember Unleashed as a free service. I do have a ZD1200 controller with support purchased, but I do not want to use this in this particular situation.
Posted on 03 Dec, 2018, in Uncategorized
Upon boot-up (cold or reload) the switch is failing to initialize the PoE module. Is there anything I can try to resolve this?ICX6610-48P Router>PoE Info: PoE module 1 of Unit 1 on ports 1/1/1 to 1/1/48 det ected. Initializing….PoE Error: Device 0 failed to start on PoE module.PoE Error: Device 1 failed to start on PoE module.Resetting module in slot 1 again to recover from dev faultPoE Info: Hard Resetting in slot 1….PoE Info: Resetting module in slot 1….completed.PoE Error: Device 0 failed to start on PoE module.PoE Error: Device 1 failed to start on PoE module.